HV Tests Software v1.2 Release Notes


Changes:

* Fixed wrong Result status display in Test #8
* Added user definable range parameters DAC1 and DAC2 in Test #8
* Fixed missing data in log file output for Test #8
* Added checks of ID, Interlock and +/-5V for new revision of Master Board in Tests #12-17
* Added support for Master Board in Test #7
* Added Interlock scheme check for Master Board in Test #12
* Removed software scaling coefficient for Master Boards Channel DAC in Tests #12-17
* Fixed writing to wrong module bus address in RDB Test #6
* Changed Interlock check order in RDB Test #1
* Fixed set value for Input HV (4kV) in RDB Test #4
* Added periodical display of voltage and current for all HV channels in RDB Test #4
* Added Input HV Voltmeter Channel (#38) check and calibration in RDB Test #10.


NOTE:
LabWindows/CVI Runtime Version 6.0 or higher should be installed on computer prior to installation of HV Tests Software

To install:
Run self-extracting archive executable HV_Tests_v1.2.exe and point to the directory where you want to install software.
or Unpack archive HV_Tests_v1.2.zip into the directory where you want to have test executables.


After that you can run tests programs (with .exe extensions) located in [YOUR_INSTALLATION_PATH]/bin and check for tests results in [YOUR_INSTALLATION_PATH]/TestResults
Any questions? Contact Alex Madorsky madorsky@phys.ufl.edu or Victor Barashko barashko@phys.ufl.edu